入驻第

购物车0
查看购物车已选择0个商品

在线交易:

在线客服

店内搜索

好友分享:

Thermo Scientific™ Restore™ Western Blot Stripping Buffer




货号:21059

规格:500 mL

交货周期:现货1-2个工作日,期货现询

运杂费: 登录后可查看运杂费

DeepBio得分:5567.2
DeepBio得分 是基于文献引用次数,影响因子,文献新近度等因素计算的客观产品评级,得分越高表明该产品经过越可靠的实验验证,质量可信度越高

  • 产品详情
  • 评价
  • 包装清单
  • 售后服务

Description

Thermo Scientific Restore Western Blot Stripping Buffer safely and effectively removes primary and secondary antibodies from nitrocellulose and PVDF membranes to allow chemiluminescent Western blots to be reprobed.

Features of Restore Western Blot Stripping Buffer:

• Saves time—no need to re-run gels and blots
• Saves costly sample—re-probe the membrane using the same target sample
• Effective—formulation is more efficient at stripping antibodies than homemade buffers
• Gentle—does not damage the target antigen during stripping allowing efficient reprobing
• Odor-free—no mercaptans means no acrid odors
• Economical—less expensive than other commercial stripping buffers

Product Details
Performing gel electrophoresis and duplicate immunoblot assays to test new primary antibodies or antibody concentrations is time-consuming and expensive. Restore Western Blot Stripping Buffer eliminates this waste when detecting immunoblots with chemiluminescent Western blotting substrates. Restore Stripping Buffer provides clean and efficient removal of primary and secondary antibodies from immunoblots without removing or damaging the immobilized antigen allowing blots to be stripped and reprobed with confidence.

Chemiluminescent Western blot detection with reagents such as Thermo Scientific SuperSignal Substrates for horseradish peroxidase is one of the most common and sensitive methods in use today. Because these substrates do not precipitate and bind to membrane surfaces, Western blots detected by chemiluminescence can be stripped with reagents that remove affinity-bound primary and secondary antibodies. To be effective, a stripping buffer must be strong enough to disassociate bound antibodies but gentle enough to leave the transferred target proteins intact on the nitrocellulose or PVDF membrane. Restore Western Blot Stripping Buffer has these characteristics.

By stripping and reprobing, there is no need to waste rare or costly samples by running multiple gels in order to probe for different targets. A single membrane from one gel can be stripped with Restore Western Blot Stripping Buffer to remove the primary antibodies. Stripping the blot takes only 15 to 30 minutes, depending on the affinity of the primary antibody. After stripping, block and reprobe with a new primary antibody. Alternatively, a blot can be stripped and reprobed with adjusted antibody concentrations to optimize conditions after obtaining initially poor results.

Applications
• Reuse a nitrocellulose or PVDF blot to detect a different target with a different primary antibody
• Reprobe a blot to correct or optimize antibody concentrations that were ineffective the first time

Protocol Summary
• Wash blot to remove chemiluminescent substrate.
• Incubate blot in Restore Western Blot Stripping Buffer for 5 to 15 minutes at 37°C (room temperature is sufficient for some antibodies).
• Remove blot and wash in Wash Buffer (TBS-T or PBS-T).
• Test for sufficient removal of antibodies.
• Perform next immunoblot experiment.

Specifications

Bulk or Custom Form: Bulk Custom Form 1
Form: Liquid
Product Line: Restore™
Product Size: 500 mL

 

Contents & storage

Storage: Upon receipt store at room temperature or 4°C. Product shipped at ambient temperature.